DRYER MAYTAG MEDC215EW1 Installed handle and seal. Door opens and closes properly. All ops normal.

Irvin F.
WASHER MAYTAG MVWX655DW1 Gear case is grinding during spin cycle wash play is not moving properly there is an oil leak underneath the unit suspensions are bottoming out main control board is not operating is not seeing the door lock; ordrng 1 W10006481 (gearcase) and 1 W10396887 (hub) and 1 W10597177 (actuator) and 1 W10609480 (washplate) and 1 W10682535 (latch) and 1 W10748956 (suspension)

Irvin F.
DRYER MAYTAG MEDC215EW1 Handle clip broken off handle. Can’t access dryer drum. Unit needs replacement handle. The temp handle in place. The gasket is tattered also. Replacing. ; ordrng 1 W10714516 (handle) and 1 W10730752 (seal-door)

Irvin F.
DRYER ELECTRIC WHIRLPOOL WFW72HEDW0 "Removed power from washer. Replaced main control, pressure switch, and bello. Completed assembly of washer. Powered unit, ran the diagnostics cycle, passed. Unit is operating fully, no leaks. All ops normal."

Irvin F.
DRYER ELECTRIC WHIRLPOOL WFW72HEDW0 "F3/E1- water level error, F8/E3- over flow, F0/E1-load detected during clean cycle. cleared the codes ran the diagnostics cycle the unit passed the test. The door is leaking the bello is rolling back. Replacing the switch, and the bello and main control. The errors came back after the test. Ordering parts. ; ordrng 1 W10448876 (water level switch) and 1 W10900506 (bellow) and 1 W10909372 (cntrl-elec)"

Irvin F.
WASHER MAYTAG MVWC565FW2 "F0/E5-OFF BALANCE, F5/E2XLOCKcx says washer won’t operate. Powered unit. The lock is pulsing. Removed power. Replaced lock. Cal unit. All ops normal."

Irvin F.
DRYER MAYTAG MEDC215EW1 S225EQThermal failure no heat. Failed cut off. Replaced thermal cut off. All ops normal. ; used 1 279816 (THERMAL CUT OFF HI) from stock

Irvin F.
DRYER MAYTAG MEDC215EW1 S225EQThermal failure no heat. Failed cut off. Replaced thermal cut off. All ops normal. ; used 1 279816 (THERMAL CUT OFF HI) from stock

Irvin F.
DRYER MAYTAG MEDC215EW1 S225EQThermal failure no heat. Failed cut off. Replaced thermal cut off. All ops normal. ; used 1 279816 (THERMAL CUT OFF HI) from stock

Timothy J.
WASHER MAYTAG MVWX655DW1 Installed parts. Ran. A service test. Unit operating as designed.

Timothy J.
WASHER MAYTAG MVWX655DW1 Installed hub assembly. Ran a calibration cycle. Ran a service test. Found the splutch assembly is broken . The gearcase looks new but all the components under neath are covered in oily grease. Unit needs a splotch assembly and actuator.

Timothy J.
WASHER MAYTAG MVWX655DW1 Checked faults 0-5. Unit has a bad hub assembly. Unit needs this part replaced.; ordrng 1 W10528947 (drive hub kit)

Irvin F.
FREEZER MAYTAG MRT118FZEM00 "upon arrival found failed evap motor. Removed panel confirmed power to the motor. Good. Replaced evap motor powered up, fan runs all operations normal."

Kenneth M.
RANGE WHIRLPOOL WFE515S0ES1 Installed new cooktop and tested unit. Unit is now working properly. Customer approves function at this time.

Kenneth M.
REFRIGERATOR WHIRLPOOL WRS321SDHZ00 Found unit to cold. Issues with damper. Damper not opening and closing properly. Causing excessive cold temps in freezer. Ordering damper. Reschedule with job number 222987; ordrng 1 W11317276 (DIFFUSER)

Irvin F.
maytag washer MVWX655DW1 Customer says unit is not finishing cycles. Found weak suspension, failed actuator, and pressure sensor errors. Replaced components and ran calibration, passed. all operations normal. Used W11116592 (CNTRL) W10913953 (Actuator) W11130362 (SUSPENSION)