Appliance Repair Casa Conejo California
Appliance Repair Specialist Rated out of 5 stars based on customer reviews
We serviced a
KITCHENAID REFRIGERATOR
Model KRFC704FPS06
Near Casa Conejo, California 91320
Rich
Job Details:
07/21/2025
"Inverter flashing 4 times, code for bad compressor. Found leak in condense, pics in SD Mobile.Replaced compressor and condenser. Pressure tested 15 minutes, no pressure drop. Pulled vacuum 10 minutes. Charged 56 Grams R600. Operating as designed..Bill double for multipleComponent replacement."
We serviced a
KITCHENAID REFRIGERATOR
Model KRFC704FPS06
Near Casa Conejo, California 91320
Sean W
Job Details:
07/18/2025
"Didnt have all items needed for repair,returning with everything needed for repair.; saved tckt"
We serviced a
KITCHENAID REFRIGERATOR
Model KRFC704FPS06
Near Casa Conejo, California 91320
Sean W
Job Details:
07/15/2025
"Both cabinets warm and thermistors are within operating range, condenser and evaporator fans are functional and turn on in test mode,ran test 40 and compressor will not turn on and system may have refrigerant leak, ordered compressor, fresh food evap,freezer evap and condenser.berified with trade partners that cxs sealed system parts and labor are covered.Sr # 7741964576; ordrng 1 W11578205 (Compressor) and 1 W11567329 (Condenser) and 1 W11565768 (Freezer evap) and 1 W11567406 (Fresh food evap)"
We serviced a
JENN-AIR OVEN
Model prg4810np
Near Casa Conejo, California 91320
Giovanni M
Job Details:
02/12/2025
"7740940888CX is complaining that the unit will not heat properly and that the top right burner wont go on high. Upon diagnosis I found the gas to be coming in as a sputter. Call Tech Line and found out that they need a new gas regulator. Unfortunately, that part is no longer service for this unit. to fix the low flame on the burner. Customer will need a new manifold piece. ; ordrng 1 W10625027 (VALVE-BRNR)"
We serviced a
WHIRLPOOL DISHWASHER
Model WDP540HAMZ0
Near Casa Conejo, California 91320
Richard
Job Details:
05/08/2024
"On arrival inspected unit unit did not give any error codes but when you were trying to run a cycle, the motor would not turn on in diagnostics or in a normal cycle. Replaced motor tested unit unit passed all tests and is working as intended. Job complete."